Handles flowing fluid temperatures:
- Rising stem bodies from -20 degrees F (-28 degrees C) to +140 degrees F (+60 degrees C)
- Swinging gate bodies from -20 degrees F (-28 degrees C) to +550 degrees F (+288 degrees C)
- Any ambient temperature from -20 degrees F (-28 degrees C) to +140 degrees F
(+60 degrees C)
Valve bodies designed to ANSI (American
NationAl Standards Institute) standards. ISO (Intemational Standards Organization)
standards also available.
All Maxon valve electric components are UL
(Underwriters Laboratories) recognized.
Various application requirements met with
manual reset or automatic reset motorized operators.